DSNJ096E csect-name CRCR ENDLRSN RBA VALUE OF rrr IS INVALID, NO TRUNCATION WILL OCCUR

Explanation

Truncation cannot take place because the RBA value specified on the active CRCR record is not equal to the RBA of a log record. rrr is the ENDLRSN specified in the active record. The ENDLRSN RBA value must match the start of a log record in a non-data sharing environment.

System action

Db2 startup is terminated.

Operator response

Notify the system programmer.

System programmer response

Confirm that the ENDLRSN value specified in the Conditional Restart control record is correct. Run the Change Log Inventory (DSNJU003) utility with the CRESTART CANCEL parameters to cancel the conditional restart. If log truncation is needed, run the DSNJU003 utility with the correct ENDLRSN value. Restart Db2.