DSNB303E csect-name A LOSS OF CONNECTIVITY WAS DETECTED TO GROUP BUFFER POOL gpbname

Explanation

Connectivity to group buffer pool gpbname was lost.

System action

Db2 disconnects from the coupling facility structure with REASON=FAILURE.

The action taken in response to this problem depends on the attempted function, as follows:
  • For a coupling facility read: SQLCODE -904 (resource unavailable) is returned to the SQL user with a reason code indicating the specific error.
  • For a coupling facility read during rollback, backout, or restart: The inaccessible page is added to the logical page list (LPL) for the page set. Message DSNB250E is issued for the first page of each data set added to the LPL.
  • For a coupling facility read during castout: The castout operation cannot complete.
  • For a coupling facility write: The changed page is added to the LPL for the page set.