PARAMETER MODULE field
The value of the PARAMETER MODULE field specifies the member name of the load module that is to be used for Db2 subsystem parameters.
Acceptable values: | 1–8 characters |
---|---|
Default: | DSNZPARM |
Update: | option 25 on panel DSNTIPB |
DSNZPxxx: | none |
The parameter module typically resides in library prefix.SDSNEXIT. To avoid conflict with members of prefix.SDSNLOAD, use DSNZPxxx, where xxx is any set of three alphanumeric characters. Db2 puts this name in the startup JCL procedure in SYS1.PROCLIB, but you can override this value by using the START DB2 command.