DSNT053I DSNTRIN WAS UNABLE TO PROCESS THE IFI READS REQUEST FOR IFCID 106: RETURN CODE = return-code, REASON CODE = reason-code, BYTES NOT MOVED = bytes-remaining

Explanation

DSNTRIN attempted to perform a synchronous read of IFCID trace record 106 but received an unexpected return code from the Db2 Instrumentation Facility Interface (IFI).
return-code
The return code from IFI.
reason-code
The reason code from IFI.
bytes-remaining
The number of bytes that did not fit in the return area and still remain in the buffer.

System action

DSNTRIN terminates.

User response

To diagnose the error, refer to the return and reason codes for information about the IFCARC1 and IFCARC2 values in the instrumentation facility communications area (IFCA). Rerun job DSNTIJRT when the cause has been corrected.

Severity

8 (error)