DSNR040I csect-name TRACKER RESTART ENDLRSN lrsn DOES NOT MATCH ENDLRSN lrsn ASSOCIATED WITH THE DATA SHARING GROUP

Explanation

In a data sharing environment, a TRKRSITE Db2 will not restart if it detects inconsistencies in the reported values for ENDLRSN. The ENDLRSN specified on the Conditional Restart Control Record does not match the ENDLRSN in the system communications area (SCA) structure for the data sharing group.

System action

Db2 startup terminates.

Operator response

Collect the SYS1.LOGREC and SVC dump, and contact the system programmer.

System programmer response

If the ENDLRSN value for this member is incorrect, take the following actions:
  • Restore the BSDS and Logs for his Tracker Db2 from the primary Db2
  • Ensure the Conditional Restart Control Record is correct
  • Restart Db2
If the ENDLRSN value in the SCA is incorrect, delete the SCA structure and restart all members of the TRKRSITE data sharing group with the same ENDLRSN.