DSNJ246I CONDITIONAL RESTART - COLD START AT RBA rrr. REPLY Y TO CONTINUE, N TO CANCEL

Explanation

The conditional restart control record in use indicates that Db2 is to be restart and that logging is to begin at the specified RBA.

System action

If Y, Db2 startup continues. If N, Db2 startup is terminated.

Operator response

Reply N if the truncation is going to occur at an undesirable point. Notify the system programmer. Reply Y to continue the cold start.

System programmer response

Rerun the change log inventory (DSNJU003) utility to modify the conditional restart record.