DSNJ150E LOG CAPTURE EXIT ABEND, EXIT DEACTIVATED
Explanation
An abnormal program interrupt was detected while executing in the installation-supplied log capture exit code (i.e. entry point DSNJW117 in load module DSNJL004). As a result of the abend, the log capture exit will no longer be active; log data will no longer be available for Exit capture/processing.
This message can only occur when an installation-supplied log capture exit (entry DSNJW117) is active for this instance of Db2.
System action
The log capture exit (entry point DSNJW117) is terminated. No further calls will be attempted for this Db2 instance. A full dump is provided for diagnostic purposes.
This message is non-scrollable. It remains highlighted on the console until you take the appropriate action.
Operator response
Notify the system programmer.
System programmer response
Determine the cause of the DSNJL004 load module (DSNJW117 entry point) abend and take corrective action.
Attention: A correctly-functioning copy of load module DSNJL004/entry DSNJW117 must be available in order to start Db2. If the problem which caused the above abend cannot be corrected, ensure that the default DSNJW117 entry (load module DSNJL004 - supplied with the Db2 release) is available during the next Db2 subsystem start.
User response
See “System Programmer Response” below.