DSNJ130I ICF CATALOG NAME IN BSDS DOES NOT AGREE WITH DSNZPARM. BSDS CATALOG NAME=name, DSNZPARM CATALOG NAME=name
Explanation
The ICF catalog name defined in DSNZPARM does not agree with the name contained in the bootstrap data set (BSDS).
System action
Db2 startup is abended.
Operator response
If you attempt to start the Db2 subsystem, you will receive this same message and abnormal termination will result until the problem is resolved.
System programmer response
Change the ICF catalog name in the BSDS to agree with the name defined in DSNZPARM during Db2 initialization. To change the ICF catalog name in the BSDS, use the BSDS change log inventory (DSNJU003) utility with the NEWCAT control statement.
User response
Notify the system programmer.
Problem determination
During log manager initialization, the ICF catalog name defined in DSNZPARM is compared to the catalog name in the BSDS to ensure that the catalog name used by the log manager during Db2 processing is correct. These names were found not to be the same.