DSNT103I THE CURRENTLY LOADED DSN6SPRM IS NOT THE MVS/XA VERSION
Explanation
A -START DB2 PARM=xxxxxxxx was issued where 'xxxxxxxx' is the version of the system parameter CSECTs. DB2® executes in a MVS/XA environment and will not execute in any other environment.
System action
The message DSNV086E is generated with a reason code of X'00E30008'. DB2 is terminated with abend code X'04F'.
Operator response
Notify the system programmer.
System programmer response
Restart DB2 with a -START DB2 PARM= command, where the parameter block that follows the 'PARM=' parameter specifies an MVS/XA version of the DB2 subsystem parameters.
Problem determination
Collect the following diagnostic items:
- Console output from the system on which the job was run, and a listing of the SYSLOG data set for the period of time that spans the failure.
- Dynamic dump, taken to SYS1.DUMPxx data set, by DB2 (04E and 04F abends).
- SVC dump (or system dump), taken to SYS1.DUMPxx data set, as result of an operator-initiated dump command or SLIP trap exit.
- Listing of SYS1.LOGREC data set, obtained by executing IFCEREP1.
- Listing of DSNZPARM module used.