Requirements for the quota enforcement peer group
Requirements must be met for peer group configuration for quota enforcement.
Before you configure the quota enforcement peer group, ensure that you meet the
following requirements.
- Setup an initial plan about a peer group. For each peer group, at least three members must be prepared for failover.
- Record the DataPower® IP address. The IP address can
be the IP address on any DataPower interface. Use the IP address to verify that all members of the
peer group can communicate to each other. This IP address uniquely identifies the DataPower Gateway. The IP address cannot be
127.0.0.1
,0.0.0.0
or::
. - All members of the peer group must run the same firmware version.
- Each peer group member must be started one by one. You cannot start all members at the same time. The first member that becomes active is considered the primary member in the peer group.