How to define standby control for B2B high availability (HA).
Procedure
- In the search field, enter ethernet.
- From the search results, click Ethernet interface.
- Click the name of the interface to edit. The Ethernet interfaces for standby control on
the primary and secondary gateways must be on the same subnet.
- Configure the standby control for HA.
- On the Standby control tab, enable standby
control.
- In the Group number field, enter the group number. The group
number of the primary and secondary gateways must be the same.
- In the Primary virtual IP address field, enter the virtual IP
address for the high availability cluster to process B2B transactions.
- Set the Enable preemption property
- Optional: In the Secondary virtual IP addresses
field, enter auxiliary virtual IP addresses. These addresses are advertised when the interface is
the active member of the standby group.
- Retain the default value of 100 for the Priority field. The
priority must be 100 on both the primary and secondary gateways.
- Click Apply to save changes to the running
configuration.
- Click Save to save changes to the persisted
configuration.
What to do next
Define B2B persistence settings for the primary and the secondary gateways.