Valid values for the Utility ID field
The Utility ID field is included in all utility profiles and is used to uniquely identify the utility to Db2, and must adhere to naming rules.
The ID must begin with a letter; the remainder can be alphanumeric or the following special characters: #, $, @, ¢, !, ¬, . If this utility profile is included in a job profile that is built for execution in a maintenance window, a utility ID that is specified in this field is ignored. For maintenace window builds, Db2 Automation Expert generates a unique utility ID for each object by using the letter “A” followed by the action ID that is assigned to the object and utility pair (for example, “A1785”).