DWW838I date time A TEMPORARY ERROR CONDITION OCCURRED DURING SYSTEM LOGGER OPERATION {IXGCONN | IXGWRITE | IXGBRWSE | IXGDELET} {CONNECT | DISCONNECT | START | READCURSOR | READBLOCK | END | ALL | RANGE} FOR LOG STREAM logstream. SYSTEM LOGGER RETURN CODE rc REASON CODE rsnc

section

CICS® VR called the system logger to access a log, which returned a temporary error condition. The system logger operation that returned the error condition is identified in the message. The return and reason codes that are shown are returned by the system logger. These return and reason codes can be interpreted by reviewing the description of errors for the appropriate system logger operation in the z/OS® MVS Programming: Assembler Services Reference.

In the message text:
date
The current date.
time
The current time.
logstream
The name of the log stream.
rc
The system logger return code.
rsnc
The system logger reason code.

section

CICS VR automatically tries the operation again every 3 seconds while the temporary error condition persists. This message is issued after every 10 tries after the first or previous issue.

Operator response

None. This is a temporary condition.