DWW267I VSAM BATCH REDO LOGGING FAILED. ASID (IN HEX): nnnn RETURN CODE (IN HEX): rc REASON CODE (IN HEX): rsnc

section

The CICS VR VSAM batch logger has detected a logging error or an application completed abnormally. Forward recovery is impossible for the updates made by the job step task that was being executed when the logging error or the abnormal termination of the VSAM application occurred.

In the message text:

Source: CICS VR (DWW1SEOX)

section

The logger encountered an error while performing logging or REDO logging was stopped at application abend or non-zero completion code.

section

CICS VR VSAM batch logging terminates for the VSAM application. The system continues processing.

Operator response

Verify the status of the CICS VR server address space or MVS system logger and restart them if they have terminated. Otherwise, contact your IBM Support Center.

The list of return codes and reason codes follows:

RETURN CODE 36
Explanation: The logger encountered an error while performing logging or REDO logging was stopped at application abend or non-zero completion code.
Reason Code Description
X'73050090' Explanation: A logging error occurred during VSAM batch logging. The job log might contain CICS VR messages for this error. Some after image log records were not written.

Programmer Response: Check for a logging problem. If the job step has completed with the 3999 code, take a new backup of the affected spheres because forward recovery of all updates made by the step is not possible.

X'73050091' Explanation: A logging error occurred while VSAM was disconnecting from the CICS VR server address space. Some after image log records were not written.

Programmer Response: Check for a logging problem. If the job step has completed with the 3999 code, take a new backup of the affected spheres because forward recovery of all updates made by the step is not possible.

X'73050098' Explanation: Back level of VSAM Batch Logger. After image log records were not written.

Programmer Response: Update the VSAM level.

X'73050099' Explanation: The VSAM application program completed abnormally or with a non-zero completion code. Some after image log records were not written.

Programmer Response: Investigate and fix the problem that caused the job step to terminate abnormally.

X'7305009A' Explanation: The VSAM application program completed abnormally or cancelled at job step termination.

Programmer Response: Investigate and fix the problem that caused the job step to terminate abnormally at job step termination.