DWW1325W VSAM sphere dddd logged on MVS log stream llll from yydddhhmmss to yydddhhmmss local time was also logged on another log stream during this time period.

section

VSAM sphere dddd has been logged on more than one log stream for the time period yydddhhmmss to yydddhhmmss local time. One of the following events might have occurred:
  • Log streams were switched while the sphere was open for processing.
  • Data was lost due to system malfunction.
CICS VR cannot handle this situation without risking data loss.

section

If this message occurred during the construction of a recovery job using the CICS VR panels, CICS VR has detected that VSAM sphere dddd has been logged on more than one log stream for the time period. During a previous log of logs scan, CICS VR messages DWW1320 and DWW1321 were issued for VSAM sphere dddd, indicating that this sphere will take data for the overlapped interval from the log stream llll. This message is accompanied by message DWW1323. The time period for the log stream that was reported in message DWW1323 was truncated to remove the overlap. CICS VR cannot handle this situation without risking data loss. A recovery job is built, unless there are other reported errors preventing the job build, but the JCL generated will cause the overlapped interval to be ignored for the log stream that was reported in message DWW1323.

If this message occurred during a batch log of logs scan, CICS VR messages DWW3120 and DWW1321 were also issued for VSAM sphere dddd during this or a previous scan. Messages DWW1320 and DWW1321 indicate that this sphere was logged on two log streams during the specified time period. The job steps in the recovery report generated for this VSAM sphere will take data for the overlapped interval from the log stream llll. This message is accompanied by message DWW1323. The time period for the log stream that was reported in message DWW1323 was then truncated to remove the overlap. A recovery report is built unless there are other reported errors preventing the report build, but the job steps in the report will cause the overlapped interval to be ignored for the log stream that was reported in message DWW1323. This could present an integrity exposure.

section

See messages DWW1320 and DWW1321 for more information. Do not run the job or use the information in the recovery report that CICS VR created for you until you ensure that all updates on the MVS log stream, reported in message DWW1322, that were ignored by CICS VR are not required. Take the actions recommended in messages DWW1320 and DWW1321.