DWW0553S Record nn1 is found out of sequence when reading backward on log dddd. The preceding record is nn2. Processing terminates.
section
Two label records are not in the correct time
sequence in log dddd. Record nn1, which
precedes record nn2 on the log, has a later time stamp.
Also, the sequence numbers of these records are not in sequence. Some possible
causes for this message are:
- Logs were archived in the wrong time sequence, or a log was archived twice in a row.
- A log was written over an older log, and the data set is not closed. This can occur when the system abends.
- The time and date were specified incorrectly during an IPL of the operating system.
- A log had data other than log records.
- The
SEQCHKR OUTOFSEQUENCE(STOP)
command. -
STOP
in the sequence checking secondary window. - No option in the out of sequence field of the sequence checking secondary window.
section
CICS® VR stops the backout and prints the reports.
section
- Batch–If logs are specified in the wrong order, contact your
local IBM® Support
Center.
If a log was not closed, close it and rerun CICS VR.
If you want to accept the error message and run CICS VR, specify either of these commands:
SEQCHKR OUTOFSEQUENCE(WARNING)
SEQCHKR OUTOFSEQUENCE(IGNORE)Remember to restore the VSAM data sets from the backup copies before you rerun CICS VR.
- Online–If logs are specified in the wrong order, correct the
order and rerun CICS VR.
If a log was not closed, close it and rerun CICS VR.
If you want to accept the error message and run CICS VR, specify either WARNING or IGNORE in the sequence checking secondary window.
Remember to restore the VSAM data sets from the backup copies before you resubmit the recovery job.