DWW0479W Log records with FCT entry name fff for the data set dddd are processed as being in variable format. But nn1 out of nn2 add or update log records did not meet variable format checks.

section

Some records on the log for file control table (FCT) entry name fff, and data set name dddd, are processed by CICS® VR as being in variable record format. Not all the records on the log for FCT fff and data set dddd are in variable record format. A total of nn2 records are processed for that data set, and nn1 add or update records on the log are not in variable record format.

If you are running CICS VR without the ISPF dialog interface, this message could be caused by an incorrect or missing FCTCOMP specification.

If you are using the ISPF dialog interface, this message could be caused by incorrect or missing input in the log format parameters secondary window.

section

CICS VR completes the recovery.

section

  • Batch–CICS VR might damage your VSAM data set. Check your data set, and correct the FCTCOMP command. If necessary, restore the data set from the backup copies, and rerun CICS VR.
  • Online–CICS VR might damage your VSAM data set. Check your data set, and correct the parameters in the log format parameters secondary window. If necessary, restore the data set from the backup copies, and resubmit the recovery job.