DWW0455S An unexpected zero sequence number is found when reading forward on log dddd. The preceding record is nn1. Processing terminates.

section

A label record with a zero sequence number was found, and the record before it (nn1) does not have the maximum sequence number (232-1). Both records are on log dddd. Some possible causes are:
  • The sequence number was reset to zero by CICS®. If you do not have a journal archive control data set (JACD), CICS resets the sequence number at every cold start and warm start. CICS VR functions correctly in this situation.
  • A zero sequence number occurred because the JACD is damaged or lost. CICS VR functions correctly in this situation.
  • A log was skipped during archiving, and the next log started with a record with zero sequence number.
  • A log contained data other than log records.
This message is issued if you specified:
  • The SEQCHKR RESETSEQUENCE(STOP) command
  • STOP in the sequence checking secondary window
  • No option in the reset sequence field of the sequence checking secondary window

section

CICS VR stops the recovery and prints the reports.

section

  • Batch–If the sequence number was reset to zero because you are not using a JACD, specify one of these commands and then rerun CICS VR:
    SEQCHKR RESETSEQUENCE(WARNING)    
    SEQCHKR RESETSEQUENCE(IGNORE)

    If you are using a JACD, find out why the zero sequence number occurred. If the JACD is damaged or lost, no action is required. If a log was skipped during archiving, rerun CICS VR after archiving the log. In other cases, check the contents of the log to see whether all records needed for recovery are present.

    If you want to accept the error message and run CICS VR, specify either of these commands: SEQCHKR RESETSEQUENCE(WARNING) SEQCHKR RESETSEQUENCE(IGNORE)

    Remember to restore the VSAM data sets from the backup copies before you rerun CICS VR.

  • Online–If the sequence number was reset to zero because you are not using a JACD, specify either WARNING or IGNORE in the sequence checking secondary window.

    If you are using a JACD, find out why the zero sequence number occurred. If the JACD is damaged or lost, no action is required. If a log was skipped during archiving, rerun CICS VR after archiving the log. In other cases, check the contents of the log to see whether all records needed for recovery are present.

    If you want to accept the error message and run CICS VR, specify either WARNING or IGNORE in the sequence checking secondary window.

    Remember to restore the VSAM data sets from the backup copies before you resubmit the recovery job.