lscptypes

Use the lscptypes command to display the session types and the storage systems that you can use with the session types.

Syntax

Read syntax diagramSkip visual syntax diagramlscptypes-help-h-?-s-l-fmtdefaultxmldelim-delimcharstanza-ponoff-hdronoff-rnumber-voffon-devtypedsds8000essstorwize-v3500storwize-v3700storwize-v5000storwize-v7000flashsystem-v7200storwize-v7000-unifiedflashsystem-v9000flashsystem-v840flashsystem-9100flashsystem-9200svcxiv

Parameters

-help | -h | -?
Lists help for the command. If you specify additional parameters and arguments, those parameters and arguments are ignored.
-s | -l
Displays the following information.
Column label Details
Copy Type The abbreviated name of the session type. For example, mgm is an abbreviation for Metro Global Mirror. The abbreviated session type name is used as a parameter value for the mksess command.
Full Name The full name of the session type. For example, Metro Global Mirror.
Device Types The storage systems that can be used with the session type. The values are: DS8000, ESS, SAN Volume Controller, STORWIZE-V3700, STORWIZE-V3500, STORWIZE-V5000, STORWIZE-V7000, STORWIZE-V7000-Unified, FLASHSYSTEM V7200, FLASHSYSTEM V9000, FLASHSYSTEM-V840, FLASHSYSTEM-9100, FLASHSYSTEM-9200 and XIV.
-fmt { default | xml | delim | stanza }
Specifies the format of the output. You can specify one of these values:
default
Specifies that the output is displayed in tabular format using spaces as delimiters between columns. This is the default value.
xml
Specifies that the output is displayed in XML format.
delim
Specifies that output is displayed in a tabular format using commas as delimiters between columns.
To use a character other than a comma as the delimiter, specify -fmt delim -delim char , where char represents the character that you want to use as the delimiter. For example, if you want to use a colon (:) as the delimiter, use the following -fmt parameter:
-fmt delim -delim :
If you use a shell metacharacter as the delimiting character, enclose the character in quotation marks or single quotation marks. A blank space is not a valid character.
stanza
Specifies that the output is displayed as one keyword-value pair per line.
-p { on | off }
Specifies whether to display one page of text at a time or all text at once.
on
Displays one page of text at a time. Pressing any key displays the next page. This is the default value when the command is run in interactive mode.
off
Displays all text at once. This is the default value when the command is run in single-shot mode.
-hdr { on | off }
Specifies whether to display the table header. You can specify one of these values:
on
Displays the table header. This is the default value.
off
Hides the table header.
-r number
Specifies the number of rows per page to display when the -p parameter is specified. You can specify a value of 1 - 100. The default value is 22.
-v { on | off }
Specifies whether to enable verbose mode. You can specify one of these values:
on
Enables verbose mode.
off
Disables verbose mode. This is the default value.
-devtype { ds | ess | storwize-v3500 | storwize-v3700 | storwize-v5000 | storwize-v7000 | flashsystem-v9000 | flashsystem-v840 | svc | flashsystem-a9000 | flashsystem-9100| flashsystem-9200| xiv }
Specifies the session types that are available for specific storage system types. The parameter values are:
  • ds: IBM® DS8000®
  • ds8000: IBM DS8000
  • ess: IBM TotalStorage Enterprise Storage Server® Model 800
  • storwize-v3500: IBM Storwize® V3500
  • storwize-v3700: IBM Storwize V3700
  • storwize-v5000: IBM Storwize V5000
  • storwize-v7000: IBM Storwize V7000
  • storwize-v7000-unified: IBM Storwize V7000 Unified
  • flashsystem-v9000: IBM FlashSystem® V9000
  • flashsystem-v840: IBM FlashSystem V840
  • flashsystem-9100: IBM FlashSystem 9100
  • flashsystem-9200: IBM FlashSystem 9200
  • svc: IBM System Storage SAN Volume Controller
  • xiv: FlashSystem/IBM Spectrum® Accelerate

Example: Listing all session types and storage systems

The following command lists all the session types that you can use.

csmcli> lscptypes

The following output is returned:

Copy Type Full Name           Device Types
======================================================================================================
fc        FlashCopy           DS8000, ESS, SVC, STORWIZE-V7000, STORWIZE-V7000-Unified,
                              STORWIZE-V5000, STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000,
                              FLASHSYSTEM V840, FLASHSYSTEM 9100, FLASHSYSTEM 9200

snap      Snapshot            XIV

mmsd      Metro Mirror        DS8000, ESS, SVC, STORWIZE-V7000, STORWIZE-V7000-Unified,
          Single Direction    STORWIZE-V5000, STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000,
                              FLASHSYSTEM V840, FLASHSYSTEM 9100, FLASHSYSTEM 9200

mmfofb    Metro Mirror        DS8000, ESS, SVC, STORWIZE-V7000, STORWIZE-V7000-Unified,
          Failover/Failback   STORWIZE-V5000, STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000, 
                              FLASHSYSTEM V840, FLASHSYSTEM 9100, FLASHSYSTEM 9200

mmfofbxiv Metro Mirror        XIV
          Failover/Failback

pmm       Metro Mirror        DS8000, ESS
          Failover/Failback 
          w/ Practice

pmmsvc    Metro Mirror        SVC, STORWIZE-V7000, STORWIZE-V7000-Unified, STORWIZE-V5000
          Failover/Failback   STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000, FLASHSYSTEM V840
          w/ Practice         FLASHSYSTEM 9100, FLASHSYSTEM 9200

gmsd      Global Mirror       DS8000, ESS
          Single Direction

gmsdsvc   Global Mirror       SVC, STORWIZE-V7000, STORWIZE-V7000-Unified,
          Single Direction    STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000, FLASHSYSTEM V840
                              , FLASHSYSTEM 9100, FLASHSYSTEM 9200

gmfofb    Global Mirror       DS8000, ESS
          Failover/Failback

gmfofbsvc Global Mirror       SVC, STORWIZE-V7000, STORWIZE-V7000-Unified, 
          Failover/Failback   STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000, FLASHSYSTEM V840
                              FLASHSYSTEM 9100, FLASHSYSTEM 9200

gmfofbxiv Global Mirror       XIV
          Failover/Failback

pgm       Global Mirror       DS8000, ESS
          Failover/Failback 
          w/ Practice

pgmsvc    Global Mirror       SVC, STORWIZE-V7000, STORWIZE-V7000-Unified,
          Failover/Failback   STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000, FLASHSYSTEM V840
          w/ Practice         FLASHSYSTEM 9100, FLASHSYSTEM 9200

pgm2s     Global Mirror       DS8000, ESS
          Either Direction
          w/ Two Site Practice

mgm       Metro Global Mirror DS8000, ESS

pmgm      Metro Global Mirror DS8000, ESS
          w/ Practice

mm_mm     Metro Mirror -      DS8000
          Metro Mirror

gmcvsvc   Global Mirror      SVC, STORWIZE-V7000, STORWIZE-V7000-Unified,
          Failover/Failback  STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000, FLASHSYSTEM V840
          w/ Change Volumes  FLASHSYSTEM 9100FLASHSYSTEM 9200

mm_gm     Metro Mirror -     DS8000
          Global Mirror
          
mm_gmp    Metro Mirror -     DS8000
          Global Mirror 
          w/ Practice

mm_gm_s3gm Metro Mirror -    DS8000
           Global Mirror 
           w/ Site 3
           Global Mirror
mm_gm_4s   Metro Mirror -    DS8000
           Global Mirror 
           w/ Site 4
           Replication

Example: Listing session types for IBM DS8000 storage systems

csmcli> lscptypes -devtype ds

The following output is returned:

Copy Type Full Name           Device Types
======================================================================================================
fc        FlashCopy           DS8000, ESS, SVC, STORWIZE-V7000, STORWIZE-V7000-Unified,
                              STORWIZE-V5000, STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000,
                              FLASHSYSTEM V840, FLASHSYSTEM 9100

mmsd      Metro Mirror        DS8000, ESS, SVC, STORWIZE-V7000, STORWIZE-V7000-Unified,
          Single Direction    STORWIZE-V5000, STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000, 
                              FLASHSYSTEM V840, FLASHSYSTEM 9100

mmfofb    Metro Mirror        DS8000, ESS, SVC, STORWIZE-V7000, STORWIZE-V7000-Unified,
          Failover/Failback   STORWIZE-V5000, STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000, 
                              FLASHSYSTEM V840, FLASHSYSTEM 9100

pmm       Metro Mirror        DS8000, ESS
          Failover/Failback 
          w/ Practice   

gmsd      Global Mirror       DS8000, ESS
          Single Direction
			
gmfofb    Global Mirror       DS8000, ESS
          Failover/Failback      					   

pgm       Global Mirror       DS8000, ESS
          Failover/Failback 
          w/ Practice     

pgm2s     Global Mirror       DS8000, ESS
          Either Direction
          w/ Two Site Practice

mgm       Metro Global Mirror DS8000, ESS

pmgm      Metro Global Mirror DS8000, ESS
          w/ Practice

mm_mm     Metro Mirror -      DS8000
          Metro Mirror

mm_gm     Metro Mirror -      DS8000
          Global Mirror
          
mm_gmp    Metro Mirror -      DS8000
          Global Mirror 
          w/ Practice

mm_gm_s3gm Metro Mirror -     DS8000
           Global Mirror 
           w/ Site 3
           Global Mirror

migration   Migration -    DS8000, ESS

mm_gm_4s   Metro Mirror -    DS8000
           Global Mirror 
           w/ Site 4
           Replication

mm_mm_4s   Metro Mirror -    DS8000
           Metro Mirror 
           w/ Site 4
           Replication

Example: Listing session types supported for an XIV® system

csmcli> lscptypes -devtype xiv

The following output is returned:

Copy Type    Full Name           Device Types
========================================================================
snap         Snapshot            XIV

mmfofbxiv    Metro Mirror        XIV
             Failover/Failback

gmfofbxiv    Global Mirror       XIV
             Failover/Failback