lscptypes
Use the lscptypes command to display the session types and the storage systems that you can use with the session types.
Syntax
Parameters
- -help | -h | -?
- Lists help for the command. If you specify additional parameters and arguments, those parameters and arguments are ignored.
- -s | -l
- Displays the following information.
Column label Details Copy Type The abbreviated name of the session type. For example, mgm is an abbreviation for Metro Global Mirror. The abbreviated session type name is used as a parameter value for the mksess command. Full Name The full name of the session type. For example, Metro Global Mirror. Device Types The storage systems that can be used with the session type. The values are: DS8000, ESS, SAN Volume Controller, STORWIZE-V3700, STORWIZE-V3500, STORWIZE-V5000, STORWIZE-V7000, STORWIZE-V7000-Unified, FLASHSYSTEM V7200, FLASHSYSTEM V9000, FLASHSYSTEM-V840, FLASHSYSTEM-9100, FLASHSYSTEM-9200 and XIV. - -fmt { default | xml | delim | stanza }
- Specifies the format of the output. You can specify one of these values:
- default
- Specifies that the output is displayed in tabular format using spaces as delimiters between columns. This is the default value.
- xml
- Specifies that the output is displayed in XML format.
- delim
- Specifies that output is displayed in a tabular format using commas as delimiters between columns.
- stanza
- Specifies that the output is displayed as one keyword-value pair per line.
- -p { on | off }
- Specifies whether to display one page of text at a time or all text at once.
- on
- Displays one page of text at a time. Pressing any key displays the next page. This is the default value when the command is run in interactive mode.
- off
- Displays all text at once. This is the default value when the command is run in single-shot mode.
- -hdr { on | off }
- Specifies whether to display the table header. You can specify one of these values:
- on
- Displays the table header. This is the default value.
- off
- Hides the table header.
- -r number
- Specifies the number of rows per page to display when the -p parameter is specified. You can specify a value of 1 - 100. The default value is 22.
- -v { on | off }
- Specifies whether to enable verbose mode. You can specify one of these values:
- on
- Enables verbose mode.
- off
- Disables verbose mode. This is the default value.
- -devtype { ds | ess | storwize-v3500 | storwize-v3700 | storwize-v5000 | storwize-v7000 | flashsystem-v9000 | flashsystem-v840 | svc | flashsystem-a9000 | flashsystem-9100| flashsystem-9200| xiv }
- Specifies the session types that are available for specific storage system types. The parameter values are:
- ds: IBM® DS8000®
- ds8000: IBM DS8000
- ess: IBM TotalStorage Enterprise Storage Server® Model 800
- storwize-v3500: IBM Storwize® V3500
- storwize-v3700: IBM Storwize V3700
- storwize-v5000: IBM Storwize V5000
- storwize-v7000: IBM Storwize V7000
- storwize-v7000-unified: IBM Storwize V7000 Unified
- flashsystem-v9000: IBM FlashSystem® V9000
- flashsystem-v840: IBM FlashSystem V840
- flashsystem-9100: IBM FlashSystem 9100
- flashsystem-9200: IBM FlashSystem 9200
- svc: IBM System Storage SAN Volume Controller
- xiv: FlashSystem/IBM Spectrum® Accelerate
Example: Listing all session types and storage systems
The following command lists all the session types that you can use.
csmcli> lscptypes
The following output is returned:
Copy Type Full Name Device Types ====================================================================================================== fc FlashCopy DS8000, ESS, SVC, STORWIZE-V7000, STORWIZE-V7000-Unified, STORWIZE-V5000, STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000, FLASHSYSTEM V840, FLASHSYSTEM 9100, FLASHSYSTEM 9200 snap Snapshot XIV mmsd Metro Mirror DS8000, ESS, SVC, STORWIZE-V7000, STORWIZE-V7000-Unified, Single Direction STORWIZE-V5000, STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000, FLASHSYSTEM V840, FLASHSYSTEM 9100, FLASHSYSTEM 9200 mmfofb Metro Mirror DS8000, ESS, SVC, STORWIZE-V7000, STORWIZE-V7000-Unified, Failover/Failback STORWIZE-V5000, STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000, FLASHSYSTEM V840, FLASHSYSTEM 9100, FLASHSYSTEM 9200 mmfofbxiv Metro Mirror XIV Failover/Failback pmm Metro Mirror DS8000, ESS Failover/Failback w/ Practice pmmsvc Metro Mirror SVC, STORWIZE-V7000, STORWIZE-V7000-Unified, STORWIZE-V5000 Failover/Failback STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000, FLASHSYSTEM V840 w/ Practice FLASHSYSTEM 9100, FLASHSYSTEM 9200 gmsd Global Mirror DS8000, ESS Single Direction gmsdsvc Global Mirror SVC, STORWIZE-V7000, STORWIZE-V7000-Unified, Single Direction STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000, FLASHSYSTEM V840 , FLASHSYSTEM 9100, FLASHSYSTEM 9200 gmfofb Global Mirror DS8000, ESS Failover/Failback gmfofbsvc Global Mirror SVC, STORWIZE-V7000, STORWIZE-V7000-Unified, Failover/Failback STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000, FLASHSYSTEM V840 FLASHSYSTEM 9100, FLASHSYSTEM 9200 gmfofbxiv Global Mirror XIV Failover/Failback pgm Global Mirror DS8000, ESS Failover/Failback w/ Practice pgmsvc Global Mirror SVC, STORWIZE-V7000, STORWIZE-V7000-Unified, Failover/Failback STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000, FLASHSYSTEM V840 w/ Practice FLASHSYSTEM 9100, FLASHSYSTEM 9200 pgm2s Global Mirror DS8000, ESS Either Direction w/ Two Site Practice mgm Metro Global Mirror DS8000, ESS pmgm Metro Global Mirror DS8000, ESS w/ Practice mm_mm Metro Mirror - DS8000 Metro Mirror gmcvsvc Global Mirror SVC, STORWIZE-V7000, STORWIZE-V7000-Unified, Failover/Failback STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000, FLASHSYSTEM V840 w/ Change Volumes FLASHSYSTEM 9100FLASHSYSTEM 9200 mm_gm Metro Mirror - DS8000 Global Mirror mm_gmp Metro Mirror - DS8000 Global Mirror w/ Practice mm_gm_s3gm Metro Mirror - DS8000 Global Mirror w/ Site 3 Global Mirror mm_gm_4s Metro Mirror - DS8000 Global Mirror w/ Site 4 Replication
Example: Listing session types for IBM DS8000 storage systems
csmcli> lscptypes -devtype ds
The following output is returned:
Copy Type Full Name Device Types ====================================================================================================== fc FlashCopy DS8000, ESS, SVC, STORWIZE-V7000, STORWIZE-V7000-Unified, STORWIZE-V5000, STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000, FLASHSYSTEM V840, FLASHSYSTEM 9100 mmsd Metro Mirror DS8000, ESS, SVC, STORWIZE-V7000, STORWIZE-V7000-Unified, Single Direction STORWIZE-V5000, STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000, FLASHSYSTEM V840, FLASHSYSTEM 9100 mmfofb Metro Mirror DS8000, ESS, SVC, STORWIZE-V7000, STORWIZE-V7000-Unified, Failover/Failback STORWIZE-V5000, STORWIZE-V3700, STORWIZE-V3500, FLASHSYSTEM V9000, FLASHSYSTEM V840, FLASHSYSTEM 9100 pmm Metro Mirror DS8000, ESS Failover/Failback w/ Practice gmsd Global Mirror DS8000, ESS Single Direction gmfofb Global Mirror DS8000, ESS Failover/Failback pgm Global Mirror DS8000, ESS Failover/Failback w/ Practice pgm2s Global Mirror DS8000, ESS Either Direction w/ Two Site Practice mgm Metro Global Mirror DS8000, ESS pmgm Metro Global Mirror DS8000, ESS w/ Practice mm_mm Metro Mirror - DS8000 Metro Mirror mm_gm Metro Mirror - DS8000 Global Mirror mm_gmp Metro Mirror - DS8000 Global Mirror w/ Practice mm_gm_s3gm Metro Mirror - DS8000 Global Mirror w/ Site 3 Global Mirror migration Migration - DS8000, ESS mm_gm_4s Metro Mirror - DS8000 Global Mirror w/ Site 4 Replication mm_mm_4s Metro Mirror - DS8000 Metro Mirror w/ Site 4 Replication
Example: Listing session types supported for an XIV® system
csmcli> lscptypes -devtype xiv
The following output is returned:
Copy Type Full Name Device Types ======================================================================== snap Snapshot XIV mmfofbxiv Metro Mirror XIV Failover/Failback gmfofbxiv Global Mirror XIV Failover/Failback