| Models - A00, A01, M01 @ 25 deg. C room ambient
|
7.2(4) |
6.8 |
56 |
52 |
| Models - A00, A01, M01 @ 35 deg. C room ambient
|
7.2(4) |
7.2(4) |
56 |
56 |
| Models - A00, A01, M01 @ 25 deg. C room ambient
Acoustical Doors Feature
codes
FC EC07 = back FC EC08 = front
|
6.6 |
6.2 |
49 |
45 |
| Models - A00, A01, M01 @ 35 deg. C room ambient
Acoustical Doors Feature
codes
FC EC07 = back FC EC08 = front
|
6.6 |
6.6 |
49 |
49 |
Notes -
- Declared level LWAd is the upper-limit
A-weighted sound power level; Declared level LpAm
is the mean A-weighted sound pressure level that is measured at the 1-meter bystander
positions.
- All measurements made in conformance with ISO 7779 and declared in conformance with ISO
9296.
- B, dB, abbreviations for bels and decibels. 1 B = 10 dB.
-
Note: Government regulations (such as the ones prescribed by OSHA or European
Community Directives) can govern noise level exposure in the workplace and might apply to you and
your server installation. This IBM system is available with an acoustical door feature that can help
reduce the noise that is emitted from this system. The actual sound pressure levels in your
installation depend upon various factors, including the number of racks in the installation; the
size, materials, and configuration of the room where you designate the racks to be installed; the
noise levels from other equipment; the room ambient temperature, and employees' location in relation
to the equipment. Further, compliance with such government regulations also depends upon various
extra factors, including the duration of employees' exposure and whether employees wear hearing
protection. IBM recommends that you consult with qualified experts in this field to determine
whether you are in compliance with the applicable regulations.
|