Rolling back a data evacuation
If the need to return the evacuated data to the original source device (rollback) arises during evacuation.
About this task
Note: You can only rollback a data evacuation for individual devices.
Procedure
- Pause the evacuation on the Source device.
- Click the Configure tab.
- Click Storage Pools on the left navigation panel.
- Click the Storage Pool to replace a device. The Storage Pool: <Pool Name> page displays.
- In the Slicestor Devices section, click Change Sets and Devices.
- In the Replace Individual Device section, click Configure Device Replacement.
-
In the Current Slicestor Devices list, select the current destination device.
The device actively shows as being in evacuation.
- Click Next.
-
In the Replacement Slicestor® Devices list, select
the current source device.
The device actively shows as being in evacuation.
- Click Confirm Replacement to confirm the swap of source and destination devices. The data evacuates from the original destination device to the original source device.