Ops panel LEDs

Ops panel LEDs indicate fault and status conditions.

The following table shows the possible conditions for the LEDs.

The following figure shows the location of the LEDs.

Figure 1. Ops panel LEDs
The rendering shows the location of the LEDs.
Table 1. Ops panel LED states
Unit ID display Power (green/ amber) Module fault (amber) Logical status (amber) Drawer 1 fault Drawer 2 fault Associated LEDs or alarms Status
X On Off Off Off Off   Aux present, overall power failed or off
X On On X X X Single beep, then double Ops panel power on (5s) test state
X On Off Off Off Off   Power on, all functions good
X On On X Off Off PSU fault LEDs, fan fault LEDs Any PSU fault, fan fault, over or under temperature
X On On X Off Off Compute module LEDs Any compute module fault
X On Flashing X Off Off   Enclosure logical fault such as VPD configuration error
X On Flashing X Off Off Module status LED on compute module Unknown compute module type installed, I2C Bus failure, or VPD configuration error
X On Flashing X Off Off PSU fault LEDs, fan fault LEDs Unknown (invalid or mixed) PSU module type installed, or I2C Bus failure (PSU comms)
X On On X Off Off DDIC fault LED, drawer fault LED Drive failure has occurred causing loss of availability or redundancy
X On X Flashing Off Off Arrays in impacted state Arrays operating background function
X On Flashing Flashing Off Off S1 Unit ID number different from "Start Of Day"
X On X X On Off Fault LED on Drawer 1 Fault present on drawer 1 (drive, cable or fanout card fault)
X On X X Off On Fault LED on Drawer 2 Fault present on drawer 2 (drive, cable or fanout card fault)
Flashing X X X X X   SES controlled enclosure identify
X = disregard