Installing the IOM
About this task
See CAUTION bullets regarding electrostatic discharge and anti-static protection in the ESD precautions section.
CAUTION:
If passive copper cables are connected, the cable must not have a connection to
a common ground/earth point.
Procedure
- Examine the IOM for damage, and closely inspect the interface connector. Do not install if the pins are bent.
- Grasp the IOM using both hands, and with the latch in the open position, orient the module and align it for insertion into IOM slot 0.
-
Ensuring the IOM is oriented as shown in the illustrations, slide it into the enclosure as far
as it will go.
An IOM that is only partially seated will prevent optimal performance of the enclosure. Verify that the module is fully seated before continuing.
-
Set the module in position by manually closing the latch
You should hear a click as the latch handle engages and secures the IOM to its connector on the back of the mid-plane. Tighten the thumbscrew to secure the latch in place.
- Reconnect the cables.