Enclosure dimensions
| Specification | Imperial units | Metric units |
|---|---|---|
| Height (enclosure, overall) | 3.46 inches | 87.9 mm |
| Width across mounting flange | 19.01 inches | 483 mm |
| Width across body of enclosure | 17.44 inches | 443 mm |
| Depthfrom front mounting flange to extremity of enclosure body | 22.71 inches | 576.8 mm |
| Depth from ops panel to furthest extremity of enclosure | 24.79 inches | 629.6 mm |
| Depth from front mounting flange to furthest extremity of enclosure | 23.74 inches | 602.9 mm |
Enclosure weights
| Component | Imperial units | Metric units |
|---|---|---|
| Storage enclosure (empty) | 10.56 lb | 4.80 kg |
| Drive carrier module | 1.98 lb | 0.9 kg |
| Dummy carrier module | 0.11 lb | 0.05 kg |
| PCM | 7.7 lb | 3.5 kg |
| Blank PCM | 1.32 lb | 0.61 kg |
| I/O module | 3.3 lb | 1.53 kg |
| Blank I/O module | 1.1 lb | 0.5 kg |
| Enclosure (fully populated) total weight (maximum) | 64 lb | 29 kg |
Environmental requirements
| Specification | Temperature range | Relative humidity | Max. Wet Bulb |
|---|---|---|---|
| Operating | 5°C to 35°C | 20% to 80% non-condensing |
28°C |
| Non-operating | -40°C to +70°C | 5% to 100% non-precipitating |
29°C |
| Specification | Measurement/description |
|---|---|
| Airflow | System must be operated with low pressure rear exhaust installation. Back pressure created by rack doors and obstacles not to exceed 5Pa (0.5 mm H2O) |
| Altitude,operating | -100to 3,048 meters (0 to 10,000 feet). Maximum operating temperature is de-rated by 1ºC for each 300 m above 900 m (2952.76 feet) |
| Altitude,non-operating | -305 to 12192m (-1 000 to 40 000ft) |
| Shock,operating | Vertical axis 5g 10ms 1/2 sine |
| Shock,non-operating | 30g 10ms 1/2 sine |
| Vibration,operating | 0.21g RMS 5-500 Hz random |
| Vibration,non-operating | 1.04g RMS 2-200 Hz random |
| Vibration, relocation | 0.3g 2-200 Hz sine 0.4 decades per minute |
Orientation and mounting:
|
19" Rack mount (2EIA Units)
|
Power Cooling Module specifications
| Specification | Measurement/description |
|---|---|
| Dimensions (size) | 84.3mmhigh x 104.5mm wide x 340.8mm long (3.32in x 4.11in x 37.03in) |
| Maximum output power | 580 W |
| Voltage range | 100–240 VAC rated |
| Frequency | 50–60 Hz |
| Voltage range selection | Auto-ranging: 90–264 VAC, 47–63 Hz |
| Maximum inrush current | 20A |
| Power factor correction | ≥95%@ nominal input voltage |
| Harmonics | MeetsEN61000-3-2 |
| Output | +5V @: 42A, +12 V:@ 38A, +5 V standby voltage @ 2.7A |
| Hot pluggable | Yes |
| Switches and LEDs | AC mains switch and four status indicator LEDs |
| Enclosure cooling | Dual axial cooling fans with variable fan speed control |