You can configure a rule to trigger an alert when a Sterling Connect:Direct® Process is placed in the Hold
Queue after it received an error.
About this task
For a rule to trigger when a Sterling Connect:Direct Process is placed in the Hold
Queue after it received an error (status = HE, Held in Error), perform the following
tasks:
Procedure
- Specify a parameter with the following settings:
Key |
Operator |
Value |
Message Id |
Matches |
CNCD061I |
- Values for Servers and Server Groups and additional parameters
can be specified to make this rule more specific if wanted.
When this rule is associated with an action that issues the Sterling Connect:Direct Release Process command, whenever
IBM® Sterling Control Center
Monitor finds a Sterling Connect:Direct Process is moved to the Hold Queue
with an HE status, it tells the managed server to release it to run again.