Falling back to a previous version to restore only configuration data

You can fall back from V6.4.0 to a previous release of IBM® Sterling Control Center Monitor to restore only your configuration data.

About this task

Important: This procedure addresses falling back to a previous release from V6.3.0
To fall back to a previous release to restore only your configuration data:

Procedure

  1. Create an installation directory for the fall back version, such as C:\Program Files\ControlCenter64.
  2. Close all IBM Sterling Control Center Monitor consoles.
  3. Stop the engine.
  4. Restore an exported \conf folder in C:\Program Files\ControlCenter640.
  5. Ask the database administrator to create a new database.
  6. Run the installer for the previous version of IBM Sterling Control Center Monitor and select the fall back installation directory as the destination folder, for example, C:\Program Files\ControlCenter43.
  7. Start the engine.
  8. Start the console from the IBM Sterling Control Center Monitor launch page.