Error processing

Messages are produced by the Event Counter Utility for common errors.

The following messages are displayed:

  • If the statRecordIds file cannot be found:
    Cannot find statRecordIds file
Note: If IBM® Sterling Control Center Monitor is installed correctly, this error does not occur.
  • If the input file that contains the connection input cannot be found:
    Reading from C:\EventCounterBad.csv
    Could not find csv input file
    java.io.FileNotFoundException: C:\EventCounterBad.csv
    (The system cannot find the file specified)
  • If the utility gets a ConnectionException and cannot connect to a Sterling Connect:Direct® Server listed in the input file:
    Connecting to 123.456.789.2;9121
      Error: Connection Exception!
      End of file in CommunicationBuffer::Receive().
  • If the utility gets a LogonException because the connection information has an invalid user ID or password:
    Connecting to 127.0.0.1;1363
       Error: Logon failed! Userid or password may be invalid.
  • If the utility cannot contact one or more Sterling Connect:Direct servers, then processing continues, but a warning is displayed before the results:
    Warning: Could not connect to nn servers out of nn.