Messages IDs specific to Sterling Connect:Express

You can use message IDs specific to Sterling Connect:Express when creating rules.

The following table lists IBM® Sterling Control Center Monitor message IDs specific to Sterling Connect:Express servers. The Sterling Connect:Express platform is denoted by the first letter of the message ID: U is UNIX and W is Microsoft Windows.
Important: Sterling Connect:Express logs errors differently than other server types supported by IBM Sterling Control Center Monitor. If you want to use the predefined Bad Return Code rule or create a rule to watch for failed Sterling Connect:Express transfers, you need to watch for non-zero return codes in the Server Status and Server Error event types in addition to the Process Step Ended event type.
Event Type Event Name Message ID Message Text

5

Server Status

UMBL124I

Monitor information - C:X INITIALIZATION COMPLETE V150-2 RUN=(C)

8

Server Shutdown

UMEL300I

Monitor ended - C:X TERMINATION COMPLETE

5

Server Status

UMIL125I

Monitor information - LARGE FILE (>2Gbytes) SUPPORT AVAILABLE

12

Server Command

URIL058I

Request information - REQUEST nnnnnnnn PURGED BY REMAPI

12

Server Command

URKL021I

Request accepted - REQUEST nnnnnnnn <- xxxxxx ACCEPTED (N)

11

Server Error

URLL145W

Request rejected - REQUEST nnnnnnnn REJECTED <- XXXXXXXX SRC=xxxx TRC=yyyyL PRC=zzzz

11

Server Error

URRL012I

Request error - REQUEST nnnnnnnn FILE cccccccc SRC=xxxx TRC=yyyyL PRC=zzzz

1

Process Step Started

UTBL132I

Transfer started - REQUEST nnnnnnnn FILE TRANSFER STARTED STRF xxxxxxxxxx

2

Process Step Ended

UTEL130I

Transfer ended - REQUEST nnnnnnnn FILE TRANSFER ENDED STRF xxxxxxxxxx

4

Process Ended

UTEL136I

Transfer ended - REQUEST nnnnnnnn RECEIVING <- cccccccc FILE FILE NUMBER OF RECORDS: nnnnnnnnnn

4

Process Ended

UTEL137I

Transfer ended - REQUEST nnnnnnnn TRANSMITTING -> cccccccc FILE FILE NUMBER OF RECORDS: nnnnnnnnnn

3

Process Started

UTKL131I

Transfer accepted - REQUEST nnnnnnnn FILE TRANSFER ACCEPTED STRF xxxxxxxxxx

11

Server Error

UTRL142E

Transfer error - REQUEST nnnnnnnn FILE ERROR DURING SELECTION TRC=yyyyL PRC=zzzz

5

Server Status

UXAL151W

Communication aborted - COMMUNICATION ABORTED WITH XXXXXXXX REQ: nnnnnnn

14

Connection Shutdown Started

UXCL139I

Communication ended - COMMUNICATION CLOSED (I) WITH: XXXXXXXX REQ: nnnnnnnnn (P) (T)

14

Connection Shutdown Started

UXDL138I

Communication ended - COMMUNICATION CLOSED (O) WITH: XXXXXXXX REQ: nnnnnnnn (P) (T)

13

Connection Started

UXOL134I

Communication started - COMMUNICATION OPENED (I) WITH: XXXXXXXX REQ: nnnnnnnn (P) (T)

13

Connection Started

UXPL133I

Communication started - COMMUNICATION OPENED (O) WITH: XXXXXXXX REQ: nnnnnnnnn (P) (T)

5

Server Status

UXRL143I

Communication error - COMMUNICATION NOT OBTAINED -> XXXXXXXX REQ: nnnnnnnnn RETRY IN: xx MINUTES

5

Server Status

UXRL144E

Communication error - REQUEST nnnnnnnn SESSION ERROR CALL NRC=nnnn

13

Connection Started

UXWL140I

Communication retry - REQUEST nnnnnnnn RETRY WITH PARTNER XXXXXXXX

5

Server Status

WMBL055I

Monitor initialization - THE MONITOR IS STARTED

5

Server Status

WMSL067I

Monitor start - MONITOR INITIALISATION IN PROGRESS...

4

Process Ended

WOIL040I

Transfer end - XXXXXXXX – DISABLED

1

Process Step Started

WTBL077I

Transfer begin - XXXXXXXX - FILE - TRANSFER STARTED (RECEIVE)

2

Process Step Ended

WTEL078I

Transfer end - XXXXXXXX - FILE - TRANSFER ENDED

3

Process Started

WTKL076I

Transfer accepted - XXXXXXXX - TRANSFER ACCEPTED

12

Server Command

WTRL081E

Client error - Cnnnnnnnn - ERROR - TRC= Axxxx SRC= xxxx NRC= xxxx ERC=xxxx

12

Server Command

WWRL035E

Client error - Cnnnnnnnn - TCP/IP RC= xxxx

13

Connection Started

WXBL021I

Communication begin - nnnnnnnnnn - COMMUNICATION OPENED (IN) WITH cccccc (p)

14

Connection Shutdown Started

WXEL022I

Communication end - XXXXXXXX - COMMUNICATION CLOSED WITH cccccc (p)