Property name | Property description | Property values |
---|---|---|
siRecordLimit | Specifies the value that is used by the Sterling B2B Integrator node service logic when IBM Sterling Control Center
Monitor requests data from monitored Sterling B2B Integrator servers. Note: If multiple
instances of IBM Sterling Control Center
Monitor are monitoring
the same Sterling B2B Integrator, each IBM Sterling Control Center
Monitor should have the same value for
siRecordLimit . If different values are used, then the first
siRecordLimit value received by Sterling B2B Integrator is cached and is used for BP
monitoring. This could lead to an incorrect value being used for BP Monitoring for some of the IBM Sterling Control Center
Monitor instances. |
Valid values are integers that are less than or equal to 50000. The default value is
4999. Attention: If a value greater than 50000 is specified, 50000 is applied.
|
webConsolePaginationThreshold | Specifies the maximum number of processes, alerts, events, or file transfers that are to be paginated on the Servers and Monitor tabs of the IBM Sterling Control Center Monitor web console. If the available number of records are more than what is defined in this property, a + sign is displayed. By default, 10,000 records are paginated. If there are more than 10,000 records, 10,000+ is displayed. | Valid values are integers. If you set a value less than or equal to 0, this property is disabled. The default value is 10000. |
webConsoleRefreshInterval | Specifies the time interval (in seconds) that the IBM Sterling Control Center Monitor web console is to be refreshed. By default, the web console is refreshed every 30 seconds. | Valid values are integers that are greater than or equal to 15. The default value is 30. Attention: If a value less than 15 is specified, 15 is applied.
|