Sterling B2B Integrator statistics table for virtual statistics for Sterling File Gateway (V_FG_STATS_LOG)
Describes the elements and element types for the properties in the V_FG_STATS_LOG table.
V_FG_STATS_LOG
Important: During the upgrade process from a release of IBM® Sterling Control Center
Monitor before V5.4.2.1, tables are
created to capture Sterling B2B Integrator activity.
If you have data that was collected from Sterling B2B Integrator before you upgrade to IBM Sterling Control Center
Monitor V5.4.2.1, or later, run the
convertB2BData utility to migrate your existing data to the Sterling B2B Integrator tables. This utility migrates data
that is previously stored in the EVENTS table to where it is stored now in the following tables: Sterling File Gateway activity (FG_STATS_LOG), protocol
activity (AFT_STATS_LOG), and business process activity (BP_STATS_LOG). Run the migration utility
after you upgrade IBM Sterling Control Center
Monitor, while the
engine is stopped. Do not run Sterling B2B Integrator
or Sterling File Gateway reports for data that was
collected before the upgrade until you migrate your data.
Element | Type | Description |
---|---|---|
E.CC_NAME | varchar | Reserved for future use. |
E.ACTION_ID | varchar | Name of an action that is called by a rule. |
E.ACTIONS_COMPLETED | bigint | Indicates whether the IBM Sterling Control Center
Monitor actions are completed. The values: Null=Actions not completed Timestamp=Actions completed This element is used for restarts. |
E.ALERT | varchar | Indicates whether an alert was triggered. The values: Null=No alert 0-3=Alert severity |
S.ARRIVEDFILE_KEY | varchar | Indicates the name of the file key for the arrived file. |
S.COMPLETE_TIME | varchar | Step Completion Time. |
S.CONS_ORG_KEY | varchar |
Sterling File GatewayConsumer Org Key. |
S.CONSUMER_DOCID | varchar | Consumer’s Document ID. |
S.CONSUMER_MSGID | varchar | Consumer’s Message ID. |
S.CREATEPROGID | varchar | Reserved for future use. |
S.CREATETS | varchar | Reserved for future use. |
S.CREATEUSERID | varchar | Reserved for future use. |
S.DATA_FLOW_ID | varchar | Data Flow ID. |
E.DATE_TIME | varchar | Date and time that the event was generated. Format yyyy/mm/dd hh:mm:ss.msmsms. |
S.DELIVCHAN_KEY | varchar | Delivery Channel Key. |
S.DELIVERY_KEY | varchar | Delivery Key. |
S.DELIVS_REMAIN | varchar | Number of Deliveries remaining. |
E.DEST_FILE | varchar | Destination file name in a copy operation. |
S.DOCUMENT_ID | varchar | Document ID. |
E.EMAIL_FLAG | bigint | This field is used by IBM Sterling Control Center
Monitor for recovery purposes. When a rule matches an event, the associated action is run. If the action
includes sending an email, this flag updates after the email is sent. Reporting on this field is not
recommended. The values: 0=No email sent >0=email sent The value is set to zero if nothing was done, but is set to the Timestamp if something was done. |
S.EVENT_ATTR_KEY | varchar | Reserved for future use. |
S.EVENT_CODE | varchar | Sterling File Gateway Message ID. |
E.EVENT_ID | bigint | Same as EVENTS.EVENT_ID. |
E.EVENT_KEY | varchar | Reserved for future use. |
E.EVENT_TYPE | bigint | Code indicating the type of event. |
E.FILE_NAME | varchar | Sterling File Gateway Arrived File Name. |
E.FILE_SIZE | bigint | Size of file that is transferred by the Sterling B2B Integrator batch. |
E.FROM_NODE | varchar | Server that sent the file. |
S.LOG_DATE_TIME | varchar | Same as EVENTS.DATE_TIME. |
S.MAILBOX_PATH | varchar | Indicates the path of the mailbox. |
S.MESSAGE_ID | varchar | Sterling File Gateway Message ID. |
S.MODIFYPROGID | varchar | Reserved for future use. |
S.MODIFYTS | varchar | Time the Sterling File Gateway was modified. |
S.MODIFYUSERID | varchar | Reserved for future use. |
E.MSG_ID | varchar | Server message ID issued with the event. |
S.NAME | varchar | Reserved for future use. |
E.NODE_ID | varchar | Server name alias. |
E.NODE_NAME | varchar | Name of server |
E.NODE_TYPE | varchar | Code indicating the type of server. The server
types: 0=IBM Sterling Control Center
Monitor 1=Sterling Connect:Direct® 2=Sterling Connect:Enterprise® 3=Sterling B2B Integrator 4=FTP Server 5=Sterling Connect:Express 7=MQ MFT |
E.ORIG_NODE | varchar | The server that initiated the process. |
S.P_FSTRUCT_KEY | varchar | Reserved for future use. |
E.PART_KEY | date | The date the event was generated. The format is yyyy-mm-dd. |
E.PERCENTAGE_COMPLETE | bigint | Percentage of a Sterling B2B Integrator process that is complete. |
E.PROC_ID | varchar | Sterling B2B Integrator process identifier. |
E.PROC_NAME | varchar | Sterling B2B Integrator process name. |
S.PROD_ORG_KEY | varchar | Producer’s key. |
E.REMOTE_NODE | varchar | Name of the remote server that is involved in the file transfer. |
S.REPLAY_AF_KEY | varchar | Arrived file key when the file is replayed. |
S.REPLAY_COMMENT | varchar | Comment entered when the arrived file is replayed. |
E.RET_CODE | varchar | Specifies a numeric code that is returned from a completed process or file transfer that
indicates failure or success. The standard return
codes: 0=Successful completion
4=Warning 8=Error 16=Catastrophic error |
S.REVIEWED | varchar | Reserved for future use. |
S.ROUTCHAN_KEY | varchar | Route Channel Key. |
S.ROUTE_EVENT_KEY | varchar | Route Event’s key. |
S.ROUTE_KEY | varchar | Route Key. |
S.ROUTES_REMAIN | varchar | Number of routes that are remaining. |
E.RULE_ID | varchar | Name of the rule that is triggered by the event. |
E.RULE_INSTANCE_ID | bigint | Unique identifier for the rule that is matching instances. |
E.SERVER_DATA_1 | varchar | Server metadata field 1. |
E.SERVER_DATA_2 | varchar | Server metadata field 2. |
E.SERVER_DATA_3 | varchar | Server metadata field 3. |
E.SERVER_DATA_4 | varchar | Server metadata field 4. |
E.SERVER_DATA_5 | varchar | Server metadata field 5. |
E.SERVER_DATA_6 | varchar | Server metadata field 6. |
E.SERVER_DATA_7 | varchar | Server metadata field 7. |
E.SERVER_DATA_8 | varchar | Server metadata field 8. |
E.SERVER_DATA_9 | varchar | Server metadata field 9. |
E.SERVER_DATA_10 | varchar | Server metadata field 10. |
E.SEQ_NUM | bigint | A number that is used to uniquely identify events that are generated at the same time. |
E.SHORT_MSG | varchar | Message text that is associated with the Message ID. |
E.SLC_FLAG | bigint | Internally used by IBM Sterling Control Center
Monitor
for recovery purposes. When an event is generated, it is sent to the SLC subsystem. This flag
indicates whether the event successfully sent to that subsystem. Reporting on this field is not
recommended. The values: 0=Event was not sent >0=Event was sent |
E.SLC_ID | text | System-assigned name for each SLC window. |
E.SLC_INSTANCE_ID | bigint | Unique identifier for each SLC window. |
E.SLC_SOURCE_1 | text | Internal field that is used for SLC recovery. |
E.SLC_SOURCE_2 | text | Internal field that is used for SLC recovery. |
E.SLC_SRC_EVENT_ID | bigint | EVENT_ID of the event that triggered the SLC. |
E.SOURCE_FILE | varchar | Source file name in a copy. |
S.START_TIME | varchar | Start time of the event. |
S.STATE | varchar | State of the event – Depending on the even type, it can be Completed or Routed. |
E.STEP_NAME | varchar | Name of the Sterling B2B Integrator process step. |
E.SUBMITTER | varchar | User ID of the process submitter. |
S.TIME | varchar | Time stamp of the event created. |
E.TRAP_FLAG | bigint | Internally used by IBM Sterling Control Center
Monitor
for recovery purposes. When a rule matches an event, the associated action is run. If the action
includes sending an SNMP trap, this flag updates after the SNMP trap is sent. Reporting on this
field is not recommended. The values: 0=No trap generated >0=Trap generated The value is set to zero if nothing was done, but is set to the Timestamp if something was done. |
E.USER_DATA_1 | varchar | User metadata field 1. |
E.USER_DATA_2 | varchar | User metadata field 2. |
E.USER_DATA_3 | varchar | User metadata field 3. |
E.USER_DATA_4 | varchar | User metadata field 4. |
E.USER_OP_FLAG | bigint | Internally used by IBM Sterling Control Center
Monitor
for recovery purposes. When a rule matches an event, the associated action is run. If the action
includes starting an OS command script, this flag is updated after the OS command script starts.
Reporting on this field is not recommended. The values: 0=No OS command started >0=OS command started The value is set to zero if nothing was done, but is set to the Timestamp if something was done. |
S.WFID | varchar | Workflow that is associated with the step, if any. |
E.XFER | varchar | The value of Y indicates a completed file transfer event. The value of N appears for all other event types. |
E.XFER_DIRECTION | varchar | The direction of the file transfer. Valid values are limited to inBound, outBound. |
E.XML_STRING | text | An XML representation of the event. |
S.CONSUMER_FILENAME | varchar | Consumer’s file name. |