Log system function

Use the Log system function to record a custom message in the event log when this system step executes.

About this task

To specify a Log system function

Procedure

  1. Enable the event log category User-defined message 1.
  2. From the General System Palette, drag a Log step onto the workflow map where you want to record a message in the event log.
  3. In Event Type Expression, enter a number such as an integer or integer expression that identifies this message.

    Specify a number above 1000; integers in the range 1 - 1000 are reserved for other events.

    If you enter an integer in the range 1 - 1000, the system will add 1000 to your entry and use this new number for your event log entry.

  4. In Event Message Expression, enter a string expression that will be recorded in the event log.

Results

For example, to record the value of the data field my_string_field in the event log, you specify the following:

  • Event Type Expression: 2000
  • EventMessage Expression: my_string_field

When the workflow runs and the Log system step executes, use the administration console to find the message in the event log:


  • Look for: Events
    In: Event Log
    Select one: Choose your event log
    Results Options: Specify F_Text (the data field that holds the message)
    Criteria: F_EventType=2000