Initialization Events
The following table details alarm and status events that occur at initialization.
Trap Event | Description | Trap Trigger | Short Message Text | Event |
---|---|---|---|---|
Initializationcomplete | The initialization of this node completed successfully. In a IBM® Connect:Direct® Plex environment, the member is named in the message text. | SITA036I | IBM Connect:Direct rel-level for z/OS Initialization Complete. | Status |
snaNotAvailable | The SNA support is temporarily unavailable, because the SNA=NO initialization parameter is specified, the VTAM ACB is inactive and could not be opened, the VTAM ACB is disabled during IBM Connect:Direct processing or the IBM Connect:Direct VTAM APPLID is already used. | SVTJ018I | SNA Support is Not Available. | Status |
snaNowAvailable | The VTAM ACB is successfully opened and IBM Connect:Direct now supports all SNA functions. | SVTJ019I | SNA Support is Now Available. | Status |
tcpNotAvailable | The TCP support is temporarily unavailable either because the TCP=NO initialization parameter is specified, the TCP/IP connection cannot be established, or the connection to TCP/IP is terminated. | STCP103I | TCP Support is Not Available. | Status |
tcpNowAvailable | The connection to TCP/IP is successful and all TCP functions are now supported. | STCP104I | TCP Support is Now Available. | Status |