Symbolic Definitions for the SYSOUT Keyword

The following table lists the subparameter fields for the SYSOUT keyword, identifies the format for the parameter, and the VPS symbolic name.

The As Documented by column states where to find additional information about the parameters. Spool Transfer indicates that the parameter is documented in this book. References to JCL parameters indicate that additional information is available in the MVS JCL documentation.

Parameter Format VPS Symbolic Name As Documented By
ADDRESS= ('adress line1', address line2', address line3, address line4) &ADDR1, &ADDR2, &ADDR3, &ADDR4 SYSOUT DD
BANNER= (‘literal 1' = value1, ‘literal 2' = value2,...)   Spool Transfer
BUILDING= ‘building identification' &BLDG OUTPUT DD
BURST= Yes or No &BURST OUTPUT DD &

SYSOUT DD

CC= ASA or Machine or NOCC   Spool Transfer
CHARS= (tablename, tablename...) &CHARS OUTPUT DD &

SYSOUT DD

CKPTLINE= nnnnn &CKPTL OUTPUT DD
CKPTPAGE= nnnnn &CKPTP OUTPUT DD
CKPTSEC= nnnnn &CKPTS OUTPUT DD
CLASS= class &CLASS OUTPUT DD
COMPACT= compaction-table-name &COMPACT  
COMSETUP= name   OUTPUT DD
CONTROL= PROGRAM SINGLE DOUBLE TRIPLE &CNTL OUTPUT DD
COPIES= nnn

(,(group value, group value,... ))

&COPIES &COPYG SYSOUT DD

OUTPUT DD

DATACK= BLOCK UNBLOCK BLKCHAR BLKPDS &DATCK OUTPUT DD
DEFAULT= Yes or No &DEFAULT OUTPUT DD
DEPT= ‘department identification' &DEPT OUTPUT DD
DEST= destination

(nodename, userid)

&DEST SYSOUT DD

OUTPUT DD

DPAGELBL= Yes or No   OUTPUT DD
FCB= fcb-name

(fcb-name, align | verify)

&FCB SYSOUT DD &

OUTPUT DD

FLASH= (overlay-name, count)

(,count)

&FLASH

&FLSCT

SYSOUT DD &

OUTPUT DD

FORMDEF= membername &FMDEF OUTPUT DD
FORMS= form-name &FORM OUTPUT DD
GROUPID= output-group &GROUPID OUTPUT DD
HOLD= Yes or No   SYSOUT DD
INDEX= nn &INDEX OUTPUT DD
JESDS= ALL JCL LOG MSG &JESDS OUTPUT DD
JOBNAME= job name &JOBNM Spool Transfer
LINDEX nn &LINDEX OUTPUT DD
LINECT= nnn &LINECT OUTPUT DD
MODIFY= module-name

(module-name, trc)

&CMOD

&CMTTC

SYSOUT DD &

OUTPUT DD

NAME= name of output separator &NAME OUTPUT DD
NOTIFY= node.userid

(node.userid, node.userid,...)

&NOTIFY1–4 OUTPUT DD
OPTJ= Yes or No &OPTCD Spool Transfer
OUTBIN= nnnnn   OUTPUT DD
OUTDISP= (normal, abnormal)   OUTPUT DD
OUTPUT= (reference)   SYSOUT DD
PAGEDEF= membername &PGDEF OUTPUT DD
PIMSG= (yes,msg-count)

(no,msg-count)

&PIMSG

&PIMCT

OUTPUT DD
PRMODE= line

page

process-mode

&PRMODE OUTPUT DD
PRTY= nnn &PRTY OUTPUT DD
ROOM= ‘room identification' &ROOM OUTPUT DD
SYSAREA= Yes

No

  OUTPUT DD
SYSOUT= (class) (class, writer-name, form-name) &CLASS

&WRITER

&FORM

SYSOUT DD
THRESHLD= nnnnnnnn &THRES OUTPUT DD
TITLE= ‘description of output' &TITLE OUTPUT DD
TOF= X'F1'   Spool Transfer
TRC= Yes

No

&TRC OUTPUT DD
UCS= character-set-code

(character-set-code, fold, verify)

&UCS OUTPUT DD

SYSOUT DD

USERDATA= (‘user data description',

‘user data description',...)

&UDATA01–16 OUTPUT DD
USERLIB= (‘library name 1',

‘library name 2',...)

&ULIB1–8 OUTPUT DD
WRITER= name &WRITER OUTPUT DD