IMMEDIATE.SHUTDOWN = I | R | (I, nnn | 60) | (R, nnn | 60)
This parameter determines how an immediate shutdown issued through the STOP CD command is executed.
Value | Description |
---|---|
I | The immediate shutdown waits for all Run Task programs to complete before
shutting down IBM® Connect:Direct®. This
value is the default nnn | 60 This value specifies the number of seconds that IBM Connect:Direct waits after starting the SHUTDOWN before it forces the DTF to terminate. If the wait time expires and IBM Connect:Direct forces a shutdown, the following message is displayed to the operator: SITB999I SHUTDOWN IMMEDIATE timed out. nnn=0 indicates that IBM Connect:Direct does not have a time limit within which it must shut down the DTF. |
R | The immediate shutdown commands functions as a
runtaskimm shutdown. It terminates all executing Run Task Processes
and shuts down IBM Connect:Direct. nnn | 60 This value specifies how many seconds IBM Connect:Direct waits after starting the SHUTDOWN before it forces the DTF to terminate. If the wait time expires and IBM Connect:Direct forces a shutdown, the following message is displayed to the operator: SITB999I SHUTDOWN IMMEDIATE timed out. nnn=0 indicates that IBM Connect:Direct does not have a time limit within which it must shut down the DTF. |
Modifiable through MODIFY INITPARMS command: NO