Stopping IBM Connect:Direct through the IUI

To issue the STOP CD command through the IBM® Connect:Direct® IUI:

  1. Select SN from the Connect:Direct Administrative Options Menu.
     node.name               STOP Connect:Direct                     hh:mm
     CMD ==>
    
              Q ==> Continue active transmissions until the end of process
    
              S ==> Continue active transmissions until the end of a step
    
              I ==> Immediately stop all active transmissions
                      (wait for RUN TASKS to complete)
    
              R ==> Immediately stop all active transmissions
                      (do not wait for RUN TASKS to complete)
    
              F ==> Force Connect:Direct to stop via an ABEND
    
                       EXTENDED.RECOVERY and C:D/Plex Options:
    
      Server ==>  ________ (C:D/Plex server name or '*' for entire C:D/Plex)or
                           'M' for C:D/Plex manager)
    
    
      Recover =>  ___      (Yes|No) Should EXTENDED.RECOVERY standby takeover?
  2. Type one of the five options on the command line.
    Refer to Stopping IBM Connect:Direct for a description of these options. Quiesce (Q) is the default.
  3. If you want to shut down a IBM Connect:Direct/Server in IBM Connect:Direct/Plex environment, type the server name in the SERVER field.

    If you want to shut down the IBM Connect:Direct/Manager, type ‘M’ in the SERVER field.

    If you want to shut down the entire IBM Connect:Direct/Plex environment, leave the SERVER field blank.

  4. If you want the extended recovery standby system to continue processing work, type Yes in the RECOVER field. Type No or leave the field blank if you do not want the extended recovery standby system to continue processing work.
  5. Press ENTER.

    A shutdown message is displayed for Immediate, Quiesce, and Step shutdowns. No message is displayed for Force shutdowns.