Token Ring 3174-R Gateway Controller Configuration

The following sample displays sample line, PU, and LU definitions used by VTAM to define a token ring 3174-R gateway controller for an LU6.2 connection:

REAL 3174 CONTROLLER, FUNCTIONS AS THE GATEWAY CONTROLLER    
D1IRR1   PU ADDR=01,
               DATMODE=HALF,  		  *
                MAXDATA=521,   			*
                MAXOUT=7,      			*
                PACING=2,      			*
                PUDR=YES,      			*
                DLOGMOD=SNX32702,		*
                MODETAB=DALLMTAB, 	*
                USSTAB=LSUSSTAB,  	*
                SSCPFM=USSSCS,    	*
                PUTYPE=2,           * 
                DISCNT=(NO),      	*
                SECNET=NO,					*
                VPACING=4,					*
                XID=YES, 					*
                ISTATUS=ACTIVE 			*
*                                     COAX PORTS
D1IRR102 LU LOCADDR=2,ISTATUS=ACTIVE
D1IRR103 LU LOCADDR=3,ISTATUS=ACTIVE
D1IRR104 LU LOCADDR=4,ISTATUS=ACTIVE
D1IRR105 LU LOCADDR=5,ISTATUS=ACTIVE
D1IRR106 LU LOCADDR=6,ISTATUS=INACTIVE
D1IRR107 LU LOCADDR=7,ISTATUS=INACTIVE
D1IRR108 LU LOCADDR=8,ISTATUS=INACTIVE
D1IRR109 LU LOCADDR=9,ISTATUS=INACTIVE
*   FOR LU6.2 ILU 
CDULU01  LU LOCADDR=0,DLOGMOD=NDM621K,RESSCB=5,ISTATUS=ACTIVE
CDULU02  LU LOCADDR=0,DLOGMOD=NDM621K,RESSCB=5,ISTATUS=ACTIVE
CDULU03  LU LOCADDR=0,DLOGMOD=NDM621K,RESSCB=5,ISTATUS=ACTIVE 
CDULU04  LU LOCADDR=0,DLOGMOD=NDM621K,RESSCB=5,ISTATUS=ACTIVE 
* 


********************************************************************** 
*     DOWNSTREAM PU OFF OF THE REAL 3174 GATEWAY CONTROLLER          * 
*     INDEPENDENT LU6.2                                              * 
*********************************************************************** 
CDUPU01  PU ADDR=02,                                                *
                DATMODE=HALF,                                       *
                MAXDATA=521,                                        *
                MAXOUT=7,                                           *
                PACING=2,                                           *
                PUDR=YES,                                           *
                DLOGMOD=SNX32702,                                   *
                MODETAB=DALLMTAB,                                   *
                USSTAB=LSUSSTAB,                                    *
                SSCPFM=USSSCS,                                      *
                PUTYPE=2,                                           *
                DISCNT=(NO),                                        *
                SECNET=YES,                                         *
                VPACING=4,                                          *
                ISTATUS=ACTIVE                                         
* 
DISPLAY2 LU LOCADDR=2,ISTATUS=ACTIVE 
DISPLAY3 LU LOCADDR=3,ISTATUS=ACTIVE

The 3174-R token ring gateway requires that the IBM® pSeries token ring adapter address match the address configured in the 3174-R.