APK919S THE CCM COMPONENT OF ACIF HAS USED UP ITS OBJECT STACK IN modulename.

Explanation

The CCM component of ACIF has run out of its object stack area. This could be a data stream error or a logic error. A begin structured field must have a matching end structured field following it in the data stream. If this requirement is not met, the CCM can run out of its object stack area.

System action

ACIF terminates.

User response

Check the data stream to make sure each begin structured field has a matching end structured field following it. If this is not true, correct the data stream and resubmit the job to ACIF. If the data stream meets the begin structured field requirement, this message indicates an internal logic error. Inform your service representative that you have received this message indicating an internal error.