APK339I DATA IN A PAGEDEF RESOURCE IS NOT VALID: THE
IDENTIFIER identifier SPECIFIED
IN THE CONDITIONAL PROCESSING CONTROL IDENTIFIER PARAMETER IN LND,
RCD, OR XMD STRUCTURED FIELD NUMBER number WAS
NOT FOUND.
Explanation
In the Line
Descriptor (LND), Record
Descriptor (RCD), or XML Descriptor (XMD) structured field, the Conditional Processing
flag had a value of B'1', indicating that the line data to be processed
by this LND, RCD, or XMD structured field is
to be compared with a value specified in a Conditional Processing
Control (CCP) structured field.
The CCP IDENTIFIER parameter in the LND, RCD,
or XMD structured field is used
to find one of the CCP structured fields in
the current page definition. However, the identifier specified in
the LND, RCD, or XMD structured field identified
in this message does not match the value specified in the CCP
IDENTIFIER parameter in any of the CCP structured fields
in the current page definition. The LND, RCD, XMD, and CCP structured fields are in the page definition.
System action
PSF stops processing the current data set and issues
aadditional messages that identify the processing environment when
the error was found.
System programmer response
If
an IBM® licensed
program was used to create the structured fields for the page definition
with the error, verify that the input to that program was valid.
If the input was valid, refer to your system's diagnosis reference
for assistance in determining the source of the problem. If the error
involves separator pages or the message data set, use the information
provided in the User Response section to correct the error.
User response
If you created the structured fields for the page definition,
correct the error and resubmit the print request. Refer to Data Stream and Object Architectures Mixed Object Document
Content Architecture Reference and Advanced
Function Presentation: Programming Guide and Line Data Reference for
more information about the structured field.
If the structured field has
no error, the error might be a PSF logic error. If you used a program
to create the structured fields for
the page definition, contact your system programmer.