APK317S DATA IN A PAGEDEF RESOURCE IS INVALID: THE LENGTH
OF COMPARISON
STRING PARAMETER VALUE IN CCP STRUCTURED FIELD ccpidentifier IS
INVALID.
Explanation
The Conditional Processing
Control (CCP) structured field has
an incorrect value.
Either the LENGTH OF COMPARISON STRING parameter
is zero, or the length of the comparison string data does not match
the length of a repeating group minus the fixed lengths of the remaining
fields of the repeating group. The CCP structured field is contained in the
page definition.
System action
ACIF stops processing
the print data set and issues
a message identifying the position of the structured field in the
data stream or resource.
System programmer response
If
an IBM® licensed
program was used to create the structured fields for the page definition
with the error, verify that the input to that program was valid.
If the input was valid, refer to your system's diagnosis reference
for assistance in determining the source of the problem.
User response
If you created the structured fields for the page definition,
correct the error and resubmit the print request. Refer to Advanced Function Presentation: Programming Guide and
Line Data Reference for more information about the structured field. If the structured field has no error, the error
might be an ACIF logic error. If you used a program to create the structured fields for the page definition,
contact your system programmer.