APK2014I DATA IN AN INPUT RECORD OR PAGEDEF RESOURCE IS NOT VALID:
THE PAGE SIZE IS NOT LARGE ENOUGH TO PLACE THE FIRST RECORD OF THE
PAGE BY USING RCD OR XMD STRUCTURED FIELD NUMBER number AND
ITS ASSOCIATED FIELD RCD OR XMD STRUCTURED FIELDS.
Explanation
The Body Record Descriptor (RCD) or XML Descriptor
(XMD) structured field selected for placing the first body record
of the page does not fit within the area of the page defined by the
bottom margin. If Field RCD or XMD structured fields are being used,
one of the Field RCD or XMD structured fields might be positioning
data beyond the bottom margin. This error prevents PSF from being
able to place the record and continuing.
System action
PSF stops processing the current data set and issues
additional messages that identify the processing environment when
the error was found.
System programmer response
If an IBM® licensed
program was used to create the structured fields for the page definition
with the error, verify that the input to that program was valid. If
the input was valid, refer to your system's diagnosis reference for
assistance in determining the source of the problem. If the error
involves separator pages or the message data set, use the information
provided in the User Response section to correct the error.
User response
If you created the structured fields for the page
definition, correct the error and resubmit the print request. Refer
to Data Stream and Object Architectures Mixed
Object Document Content Architecture Reference and Advanced Function Presentation: Programming Guide and
Line Data Reference for more information about the structured
field. If the structured field has no error, the error might be a
PSF logic error. If you used a program to create the structured fields
for the page definition, contact your system programmer.