APK2007S DATA IN A PAGEDEF RESOURCE IS NOT VALID: THE FIELD RCD POINTER
VALUE IN RCD STRUCTURED FIELD NUMBER number WILL
CAUSE AN INFINITE LOOP.
Explanation
The FIELD RECORD DESCRIPTOR POINTER parameter
in the Record Descriptor (RCD) structured field identified in this
message caused an infinite-loop condition. The RCD structured field
is contained in the page definition.
System action
PSF stops processing the current data set and issues
additional messages that identify the processing environment when
the error was found.
System programmer response
If an IBM® licensed
program was used to create the structured fields for the page definition
with the error, verify that the input to that program was valid. If
the input was valid, refer to your system's diagnosis reference for
assistance in determining the source of the problem. If the error
involves separator pages or the message data set, use the information
provided in the User Response section to correct the error.
User response
If you created the structured fields for the page
definition, correct the error and resubmit the print request. Refer
to Data Stream and Object Architectures Mixed
Object Document Content Architecture Reference and Advanced Function Presentation: Programming Guide and
Line Data Reference for more information about the structured
field. If the structured field has no error, the error might be a
PSF logic error. If you used a program to create the structured fields
for the page definition, contact your system programmer.