Connecting to a Guardium asset data source

The Guardium Connected Assets and Risk connector can be run in the IBM Security QRadar® Suite Software cluster. The connector incrementally synchronizes the contents of the IBM Security Guardium Data Protection asset databases with the data that is managed by the Connected Assets and Risk service.

Before you begin

Collaborate with an IBM Security Guardium administrator who can configure Guardium and obtain the required information.

The following prerequisites must be in place.

  • IBM Security Guardium Data Protection 11.3 environment.
  • Set up Compliance Monitoring to tag data sources that containing the following data.
    • General Data Protection Regulation (GDPR), Payment Card Industry (PCI), or California Consumer Privacy Act (CCPA) data
    • Sensitive data
      • Select Sensitive data found by Classification-Distributed.
      • Distributed report must be configured and scheduled.
      • The option to Gather Data From must be set to the Guardium Managed Units where the Classification is run.
      • The Classification rule Category must be set to Sensitive.
  • To obtain vulnerability data, set up and schedule Vulnerability Assessment and enable Quick Search.
  • To obtain data on users who pose a security risk, Risky Users, enable Active Risk Spotter.

Obtain the following information:

  • Security credentials (client ID and secret, username, and password). The client secret is obtained by using the following Guardium command-line interface command:
    cli>grdapi register_oauth_internal_client getEncrypted=false grant_types=password module=UDI
  • Central Manager IP address and port, and the Server Name Indicator (SNI).

About this task

Procedure

  1. Log in to IBM Security QRadar Suite Software.
  2. From the menu, click Connections > Data sources.
  3. On the Assets tab, click Connect an asset.
  4. Click Guardium, then click Next.
  5. Configure the connection to allow IBM Security QRadar Suite Software to connect to the data source.
    1. In the Connector name field, assign a name to uniquely identify the data source connection.
      Tip: Only alphanumeric characters and the following special characters are allowed: - . _
    2. In the Connector description field, write a description to indicate the purpose of the data source connection.
      Tip: Only alphanumeric characters and the following special characters are allowed: - . _
    3. In the Edge gateway (optional) field, specify which IBM Security Edge Gateway to use.

      To use the Edge Gateway to host the containers that are required for communication between the data sources and IBM Security QRadar Suite Software, select an Edge Gateway. The Edge Gateway must be version 1.6 or later. It can take up to 5 minutes to establish the connection to the Edge Gateway.

      Important: If you have a firewall between your IBM Security QRadar Suite Software cluster and the data source target, use the Edge Gateway to host the containers.

      For more information, see Edge Gateway.

    4. In the Frequency field, set how often the connector imports data from the data source, in minutes.
      The value must be an integer.
      For example, a value of 60 causes the connector to run every 60 minutes.
      If the data source doesn't have many assets, or you don't want to import data often, reduce the frequency.
  6. Click Add a Configuration.
  7. Configure identity and access.
    1. Configure identity and access.
      Table 1. Configuration parameters
      Parameter Description
      Configuration Name Enter a unique name to describe the access configuration and distinguish it from the other access configurations for this data source connection that you might set up. Only alphanumeric characters and the following special characters are allowed: - . _
      Configuration Description Enter a unique description to describe the access configuration and distinguish it from the other access configurations for this data source connection that you might set up. Only alphanumeric characters and the following special characters are allowed: - . _
      Password Enter your IBM Security Guardium password.
      Server Enter your IBM Security Guardium data source server.
      Username Enter your IBM Security Guardium username.
      Api Key Enter your IBM Security Guardium API key.
    2. Click Add.
    3. To save your configuration and establish the connection, click Done.
  8. To edit your configurations, complete the following steps:
    1. On the Assets tab, select the data source connection that you want to edit.
    2. In the Configurations section, click Edit Configuration (Edit configuration icon).
    3. Edit the identity and access parameters and click Save.

Results

The connector imports data from the data source. The connector imports data again at the interval that you set in the Frequency field.

Tip: After the data source is connected, it takes some time for the initial data retrieval based on the frequency that is specified in the Frequency parameter. During this time, the data source appears as unavailable. After the data retrieval is complete, the data source shows as connected. To maintain the connection status, a polling mechanism is initiated to verify the connection periodically.

You can add other connection configurations for this data source that have different users and different data access permissions.

What to do next

Test the connection by searching for an IP address in IBM Security Data Explorer that matches an asset data source. In Data Explorer, click an IP address to view its associated assets and risk.

To use Data Explorer, you must have data sources that are connected so that the application can run queries and retrieve results across a unified set of data sources. The search results vary depending on the data that is contained in your configured data sources. For more information about how to build a query in Data Explorer, see Build a query.