Managing sensors
About this task
You can view list of available sensors which are configurable. Individual sensor can be enabled or disabled by toggle in status column.
modified tag next to sensor name indicates modification in sensor configuration.
Procedure
To manage sensors of the database:
- Access the console.
-
From the navigation menu, select Admin > Sensor configuration.
By default, following sensors are available and enabled on the Informix instance. Allowing users to add new sensors is under consideration for future releases:
Sensor Default Frequency Default data Retention Checkpoint Default run interval frequency is 1 minute 30 Days Session Statistics Default run interval frequency is set to 15 Seconds 30 Days Dbspace Usage Default run interval frequency is set to 5 Minute 30 Days Memory Default run interval frequency is set to 1 minute 30 Days OS Memory Default run interval frequency is set to 15 Seconds 30 Days - User can update sensor configuration by clicking on pencil icon next to status toggle which is visible on hover on row.
-
Update button will only be enabled if user made changes in the configuration otherwise it will
be disabled.
Following are configurable fields for a sensor:
Field Description Run interval Any numerical value (Frequency) Duration List: Drop-down with options (second, minute, hour, day, week, month) Data Retention Interval Numeric: Sensor’s data will be cleared after specified number of days. Indefinite Toggle: Sensor's data will never be cleared if this option is turned on. If it is turned off need to specify data retention interval value. - Confirmation prompt will be displayed when you try to navigate to different page without saving changes on alert configuration page.
-
Confirmation prompt provides following actions:
- Cancel: Close the prompt and stay on the alert configuration page.
- Discard: Discard any unsaved changes and navigate to the other page.
- Save: Save the current unsaved changes and navigate to the other page.
Note:- Save button will be enabled only if there are any modifications to any of the sensor configuration.