ProbeWatch messages
During normal operations, the probe generates ProbeWatch messages and sends them to the ObjectServer. These messages tell the ObjectServer how the probe is running.
The following table describes the ProbeWatch messages that the probe generates. For information about generic Netcool/OMNIbus ProbeWatch messages, see the IBM Tivoli Netcool/OMNIbus Probe and Gateway Guide.
ProbeWatch message |
Description |
Triggers/causes |
---|---|---|
Unable to open file: FileX - ErrorY Unable to write to file: FileX - ErrorY Only managed to write NUM out of MAX_NUM characters Unable to open file: FileX - ErrorY Shutting down streamcapture file (Where FileX is a filename and ErrorY is a file error.) |
The probe could not open the file specified by the ProbeWatch message. |
Permissions are not set correctly for the specified file or there is not enough disk space available. |
Connection Lost | The probe lost the connection to the host. |
The device has dropped the connection to the probe. |
Disconnect Sequence failure | The probe failed to disconnect cleanly from the Tandem device. |
The memory location that stores the connection details has been corrupted. |
Only managed to write X out of Y characters | The probe could not write to the file specified by the ProbeWatch message. |
The file permissions are not set correctly. |