Data acquisition

Each probe uses a different method to acquire data. Which method the probe uses depends on the target system from which it receives data.

The Probe for Samsung BSM connects to a Samsung Base Station Manager device using the DNS of the device host and the port number through which the host accepts Telnet connections. The DNS and port number values are specified using the Host and Port properties in the properties file. Once the device is connected to the probe, the alarm events start flowing automatically to the probe and are then parsed to create appropriate tokens. While parsing, the probe reads one event at a time using \030 as the start delimiter, and \031 as the event terminator.

The probe only processes events that are of the following types:
  • Normal alarm
  • Fault message
  • Status message

The probe discards events of all other types.

Data acquisition is described in the following topics: