Summary
Each probe works in a different way to acquire event data from its source, and therefore has specific features, default values, and changeable properties. Use this summary information to learn about this probe.
The following table provides a summary of the Probe for Open NerveCenter.
Probe target |
Open NerveCenter |
Probe executable names |
nco_p_nervecenter |
Patch number |
4.0 |
Probe supported on |
For details of supported operating systems, see the following Release Notice on the IBM Software Support Website: Note: This probe is supported on HP-UX version 11.11, but not version 11.0.
|
Properties files |
$OMNIHOME/probes/arch/nervecenter.props |
Rules files |
$OMNIHOME/probes/arch/nervecenter.rules |
Requirements |
A currently supported version of IBM Tivoli Netcool/OMNIbus or IBM Cloud Pak for AIOps. For details of any additional software that this probe requires, refer to the description.txt file that is supplied in its download package. |
Connection method |
TCP/IP |
Remote connectivity |
The Probe for Open NerveCenter connects to the ObjectServer and waits for a connection from the NerveCenter Platform Adapter Server on the port specified by the TCPPort property. |
Multicultural Support |
Not Available |
Peer-to-peer failover functionality |
Available |
IP environment |
IPv4 or IPv6 Note: The probe is supported
on IPv6 when running on IBM Tivoli Netcool/OMNIbus 7.4.0.
|
Federal Information Processing Standards (FIPS) |
IBM Tivoli Netcool/OMNIbus uses the FIPS 140-2 approved cryptographic provider: IBM Crypto for C (ICC) certificate 384 for cryptography. This certificate is listed on the NIST website at http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/1401val2004.htm. For details about configuring Netcool/OMNIbus for FIPS 140-2 mode, see the IBM Tivoli Netcool/OMNIbus Installation and Deployment Guide. |