ProbeWatch messages

During normal operations, the probe generates ProbeWatch messages and sends them to the ObjectServer. These messages tell the ObjectServer how the probe is running.

The following table describes the ProbeWatch messages that the probe generates. For information about generic Netcool/OMNIbus ProbeWatch messages, see the IBM Tivoli Netcool/OMNIbus Probe and Gateway Guide.

Table 1. ProbeWatch messages 

ProbeWatch message

Description

Triggers/causes

Corrupt message from NerveCenter

The message header does not correspond to the expected format.

The probe has received either an invalid Connection Request message or an invalid Exit Notification message from NerveCenter.

Going Down

The probe is shutting down.

The probe is shutting down after performing the shutdown routine.

Need to Start the paserver

The PA needs to be restarted.

The PA server lost connection to the probe.

No events received for n seconds

No new events have been received for the specified number of seconds.

The probe has received no events for the time specified by the Inactivity property.

Out of memory

The probe successfully completed an advanced filtering registration.

The probe failed to allocate space using malloc.

Running ...

The probe is running normally.

The probe has just been started up.

Unable to get events

A problem occurred while trying to obtain the syslog log entries.

Either there was a problem with one of the components in the path prefix of the log file or named pipe (FIFO) (such as search permission is denied for the component) or there was a license or a connection failure.