Connecting to the CORBA interface
The probe acts as an Integration Reference Point (IRP) Manager and connects to the ZTE EMS using a 3GPP CORBA interface. The probe connects to the interface using Interoperable Object Reference (IOR) files.
Before it begins retrieving events from the ZTE EMS,
the probe acquires the EntryPointIRP CORBA object.
It gets this from the local IOR file specified by the EntryPointIrpFile property.
After
it has acquired the EntryPointIRP object, the probe
acquires the AlarmIRP and NotificationIRP objects.
It needs the AlarmIRP object to perform resynchronization
and the NotificationIRP object to get real time alarms.
The
probe uses the value specified by the AlarmIrpName property
to locate the AlarmIRP object within the EntryPointIRP object.
It uses the value specified by the NotificationIrpName property
to locate the NotificationIRP object within the EntryPointIRP object.
Using FTP
If the Entry Point IRP file is on a remote system, the probe uses an FTP command to retrieve it. To enable this, you must specify the following value for the EntryPointIrpFtpCommand property:
ftp://user:password@host/path
Where user and host are the user name and host name of the Entry Point IRP server, password is specified by the FtpPassword property, and path is the location of the Entry Point IRP file as specified by the EntryPointIrpFile property.