ProbeWatch messages
During normal operations, the probe generates ProbeWatch messages and sends them to the ObjectServer. These messages tell the ObjectServer how the probe is running.
The following table describes the ProbeWatch messages that the probe generates. For information about generic Netcool/OMNIbus ProbeWatch messages, see the IBM Tivoli Netcool/OMNIbus Probe and Gateway Guide.
ProbeWatch message |
Description |
Triggers/causes |
|---|---|---|
Error allocating memory for ProbeWatchString |
An error occurred when allocating memory. |
There is insufficient memory to complete the operation. |
Unable to open file: settings.sStreamFile - err_str |
The probe is unable to open the stream capture file. |
The file permissions are not set correctly or the disk is full. |
Status: Connection received from psockGetHost(newSockId) |
A connection was received from a specific host. |
A connection was received from a specific host. |
Status: Connection closing from psockGetHost(sockNodeptr->psid) |
A connection to a host is being closed. |
A connection to a host is being closed. |
Illegal port: settings.port |
The port number given in the message is not valid. |
The port number specified by the PortNumber property might not be in the correct format, or there is a problem with the connection to the Nokia-Siemens EWSD system. |
Only managed to write iReturnVal out of iRawBufferCounter characters |
The probe cannot write data out. |
The disk is full. |
Running ... |
The probe is running normally. |
The probe has just been started up. |
Shutting down stream capture file : settings.sStreamFile |
The probe is closing the stream capture file. |
The probe is shutting down. |
Unable to get events |
A problem occurred when trying to obtain the syslog log entries. |
There was a problem initializing the connection due to insufficient memory or (if this message was sent after some events had been parsed) there was a license failure or a connection failure. |
Going Down ... |
The probe is shutting down. |
The probe is shutting down after performing the shutdown routine. |
Failed to send "Going Down ..." ProbeWatch message |
The probe failed to send a Going Down signal to the process during shutdown. |
The setting for the ProbeWatch message has failed. |