ProbeWatch messages
During normal operations, the probe generates ProbeWatch messages and sends them to the ObjectServer. These messages tell the ObjectServer how the probe is running.
The following table describes the raw ProbeWatch error messages that the probe generates. For information about generic error messages, see the IBM Tivoli Netcool/OMNIbus Probe and Gateway Guide (SC14-7608).
ProbeWatch message |
Description |
Triggers or causes |
---|---|---|
Communication failure - lost connection to NoticiationIRP Failed to get subscripton status CORBA TIMEOUT Exception while trying to get subscription status from NotificationIRP Failed to connect to NotificationIRP: ae.reason Shutting down Failed to Connect: Either, the server is not running, the IOR is out of date, or probe cannot reach remote Server CORBA.OBJECT _NOT_EXIST Exception: Lost connection to NotificationIRP CORBA.TRANSIENT Exception: Lost connection to NotificationIRP |
The probe has failed to get the subscription status from the Notification IRP. |
The notification service is not available. |
Connection to NotificationIRP server has been established |
The probe has successfully established a connection to the Notification IRP. |
The probe has successfully subscribed to the Notification service. |
Detaching subscription |
The probe is disconnecting from the Notification IRP. |
Either the probe has not received any events for the specified timeout period, the probe is shutting down, or the probe has received a stop signal. |
END SYNCHRONIZATION |
The probe is closing the synchronization process. |
The probe has finished receiving alarms from the alarm list. |
Failed to get IRP Outline (GetIRPOutline exception caught when calling get_IRP_outline) Failed to get IRP reference (GetIRPReference exception caught when calling get_IRP_reference) Failed to get IRP references - invalid parameter (InvalidParameter exception caught when calling get_IRP_reference) |
The probe could not get either the AlarmIRP or the Notification IRP object. |
The AlarmirpName or NotificationirpName properties have incorrect values. |
Failed to listen for commands on port number listening_port |
The probe could not open the socket specified by the port to listen for commands. |
The specified port is in use for another process. |
Failed to log in to interface (InvalidParameter exception caught when calling get_IRP_outline)s |
The probe could not login to the Nokia NetAct 3GPP server. |
The Nokia-Siemens NetAct server is not running correctly. There is a connection error with the Nokia-Siemens NetAct server. The IOR is out of date. The probe does not have appropriate permissions required to log in to the Nokia-Siemens NetAct server. |
Going Down |
The probe is shutting down. |
The probe has started shutting down the connection. |
Inactivity: No events received for timeout seconds |
The probe has exceeded the time out period already set. |
The probe did not receive events for the specified period. |
Invalid IRPVersion (InvalidIRPVersion exception caught when calling get_IRP_outline)) |
The probe could not get the Notification IRP object due to invalid IRP version. |
Incorrect value set for the NotificationIrpVersion property. |
NetcoolIRPManager: Failed to find IOR file alarmirp_ior_file |
The probe has failed to get the IOR file specified. |
The AlarmirpFile property in the properties file has an incorrect value. |
NetcoolIRPManager: Failed to find IOR file ior_file g |
The probe could not find the IOR file specified. |
The AlarmirpFile or NotificationirpFile properties have incorrect values. |
NetcoolIRPManager: Failed to find IOR file notificationirp_ior_ file |
The probe has failed to get the IOR file. |
The NotificationirpFile property has an incorrect value. |
PermissionDenied (PermissionDenied exception caught when calling get_IRP_outline)s |
The probe could not login to the Nokia-Siemens NetAct server. |
The probe does not have appropriate permissions required to log in to the Nokia-Siemens NetAct server. |
Running |
The probe is successfully running. |
The probe has started functioning. |
START SYNCHRONIZATION |
The probe is synchronizing the events. |
The probe has started receiving alarms from the alarm list. |
SYNCHRONIZATION FAILED |
The probe could not get new alarms. |
The probe failed to get the alarm list, or failed to perform resynchronization of alarms. |
Unable to get events |
The probe could not get events from Nokia-Siemens NetAct. |
The probe has failed to get events. |
Unexpected fatal error when connecting to interface Unexpected fatal error when getting IRP reference from Entry Point IRP Unexpected fatal error while getting IRP Outline Unexpected fatal error, failed to connect |
The probe has received a fatal error message from the GIF/FM process. |
The error message contains information about the cause of the fatal error. |
Will listen for commands on port number listening_port |
The probe is listening for commands on the port specified. |
The port specified is ready to receive commands. |